2026-11-22 8357 Resale Inspection
- Patio unauthorized modification. Concrete cannot be used as fill around the patio pad, as per the Sussex Square ByLaws Article VII Section 1 (a) which requires foundation planting areas to be maintained by the unit owner using plants similar to the original design, not concrete. Concrete also violates Article VIII Section 3 (b) altering the natural flow of drainage water.
- Patio fence needs leveled. The panel adjacent to 8359 slopes down and needs to be leveled.
- Real estate sign must be removed from the common area. It can be placed in the window or the door of the unit.
- Concrete patio pad is pulling away from brick wall of unit and needs repaired. Repair and normal maintenance of the patio is the homeowners responsibility as per the Declaration. Recommended repair as follows (Since the patio is otherwise solid and level):
- Clean out the gap well (shop-vac and stiff brush).
- Insert a foam backer rod to about ½” below the surface.
- Apply a self-leveling polyurethane or hybrid sealant rated for exterior horizontal joints (e.g. SikaFlex Self-Leveling Sealant or Quikrete Advanced Polymer).
- These will expand/contract with temperature changes and prevent water intrusion.
- Avoid rigid fillers like mortar—they’ll crack again.
- If desired, you can finish with a light dusting of dry sand over the sealant before it skins over, to match the concrete color and reduce tackiness.
See pictures here below (Click on one to sequence through and see the whole image.)